This page (revision-17) was last changed on 18-Apr-2021 19:06 by JianSun

This page was created on 11-Jun-2009 23:40 by JianSun

Only authorized users are allowed to rename pages.

Only authorized users are allowed to delete pages.

Page revision history

Version Date Modified Size Author Changes ... Change note
17 18-Apr-2021 19:06 5 KB JianSun to previous
16 23-Jun-2009 16:40 5 KB JianSun to previous | to last
15 23-Jun-2009 16:09 4 KB JianSun to previous | to last
14 23-Jun-2009 16:07 4 KB JianSun to previous | to last
13 23-Jun-2009 16:03 4 KB JianSun to previous | to last
12 23-Jun-2009 16:00 4 KB JianSun to previous | to last
11 12-Jun-2009 16:31 4 KB JianSun to previous | to last
10 12-Jun-2009 14:40 3 KB JianSun to previous | to last
9 12-Jun-2009 14:35 3 KB JianSun to previous | to last
8 12-Jun-2009 13:12 1 KB JianSun to previous | to last
7 12-Jun-2009 12:35 1 KB JianSun to previous | to last
6 12-Jun-2009 12:01 1 KB JianSun to previous | to last
5 12-Jun-2009 11:59 1 KB JianSun to previous | to last
4 12-Jun-2009 11:17 1 KB JianSun to previous | to last
3 12-Jun-2009 10:08 686 bytes JianSun to previous | to last
2 12-Jun-2009 10:03 678 bytes JianSun to previous | to last
1 11-Jun-2009 23:40 568 bytes JianSun to last

Page References

Incoming links Outgoing links
Eis40June...nobody

Version management

Difference between version and

At line 1 changed 2 lines
[{ALLOW view jsun,ms2,DaveWilliams,LouiseHarra}]
[{ALLOW edit jsun,ms2,DaveWilliams,LouiseHarra}]
[{ALLOW edit EISMainUsers}]
[{ALLOW view Anonymous}]
At line 13 added 3 lines
\\
\\
At line 17 changed one line
''40" slot, 15 scans, time duration: roughly 6 minutes''
''40" slot, 15 scans, time duration: roughly 3 minutes''
At line 24 added 2 lines
\\
\\
At line 34 added 2 lines
\\
At line 38 added one line
\\
At line 32 removed one line
At line 45 added one line
\\
At line 50 added 2 lines
\\
\\
At line 59 added one line
\\
At line 50 removed one line
At line 63 added 3 lines
[click here to see EIS data list | https://vsolar.mssl.ucl.ac.uk/SolarB/ThumbsConn_js2.jsp?startdate=2008-01-07+00%3A52&enddate=2008-01-08+00%3A52&Instrument=Thumbnail&Instrument=Movie&Submit=Submit+entry]
At line 68 added 2 lines
\\
At line 76 added 2 lines
\\
At line 84 added 2 lines
\\
At line 88 added one line
\\
At line 90 added 7 lines
''1" fitted velocity and the deconvolution velocity (side by side)''
[{Image src='images/eis40/eis1scan_vs_40scan_recon_vel_FOV.png'}]
\\
\\
At line 103 added 2 lines
\\
At line 80 changed one line
* Due to having only two projections (order_0 & 1 images), the deconvolution is not good enough to reveal small or changed-rapidly structures. But considering 1" scanning usually takes long time to finish (in this case, 80 minutes for a small FOV), it is also not good enough to observe fast-changing features. So it looks the slot deconvolution will be useful for, at leat, synoptic review(?)
\\
At line 111 added 4 lines
* Due to having only two projections (order_0 & 1 images), the deconvolution is not good enough to reveal small or changed-rapidly structures. But considering 1" scanning usually takes long time to finish (in this case, 80 minutes for a small FOV), it is also not good enough to observe fast-changing features. So it looks the slot deconvolution would be useful for, for example, synoptic velocity review(?)
\\
At line 86 changed one line
- Instrument response is different, eg, PSF
- Instrument response is different, eg, response fuctions & PSF
At line 88 changed one line
- Spectral resolution is different, eg, TRACE covers wider for FeXII 195 line compared with EIS 195 line (according to drw)
- Spectral resolution is different, eg, TRACE covers wider range for FeXII 195 line compared with EIS 195 line (according to drw)
At line 90 changed one line
- images from TRACE & EIS may have different distortions and alias, which makes alignment difficult
- images from TRACE & EIS may have different distortions and alias, which makes alignment difficulties
At line 127 added 2 lines
\\
At line 96 changed one line
*
\\
At line 133 added one line
* If shifts order-plus images a few pixels along X-axis prior to deconvolution procedure, the reconstructed velocity maps will have slightly differences compared with no X shifts result:
At line 135 added 47 lines
''Full FOV deconvolution: X shifts are -3, -2, -1, 0, 1, 2, 3 pixels from left to right and top to bottom''
[{Image src='images/eis40/vel_iter_3pix.png'}]
\\
''Small FOV deconvolution: X shifts are -3, -2, -1, 0, 1, 2, 3 pixels from left to right and top to bottom''
[{Image src='images/eis40/vel_iter_3pix_FOV.png'}]
\\
EIS study 235 – PRY_slot_context for large slot context
__Details__:
40” slot, 14 scans, spectral window width: 48pix, Y-height: 512pixs\\
exposure time: 10s, duration: 3m6s, 15 lines\\
Data obtained on 07-Jan-2008, 5 fits files\\
TRACE 195A data is used as order-0 image: tri20080107.0600
__Details__:
FeXII 195A line, 1K by 1K size, 29 frames\\
processed by standard TRACE routines\\
[{Image src='images/eis40/eis_trace_flist.png'}]
\\
TRACE movie from tri200807107.0600 (Red color-table, log scale applied)
[click here | https://vsolar.mssl.ucl.ac.uk/eiswiki/images/eis40/trace20080107.0600.mov]
\\
EIS intensity and reconstructed velocity movie (Red color-table, log scale applied)\\
5 frames, time range: 07-Jan-2008 06:16 ~ 06:28
[click here | https://vsolar.mssl.ucl.ac.uk/eiswiki/images/eis40/eis_int_vel_v0_log.mov]
\\
----
For your information:
[Ignacio Ugarte-Urra: using 40" slot to do plasma diagnostics: electron density and DEM analysis|https://vsolar.mssl.ucl.ac.uk/eiswiki/Wiki.jsp?page=SlotDiagnostics]