This page (revision-7) was last changed on 07-Dec-2016 14:14 by PeterYoung

This page was created on 01-Jun-2010 14:42 by ViggoHanst

Only authorized users are allowed to rename pages.

Only authorized users are allowed to delete pages.

Page revision history

Version Date Modified Size Author Changes ... Change note
7 07-Dec-2016 14:14 3 KB PeterYoung to previous
6 07-Jun-2010 21:41 3 KB PeterYoung to previous | to last
5 07-Jun-2010 21:40 3 KB PeterYoung to previous | to last
4 07-Jun-2010 21:39 3 KB PeterYoung to previous | to last
3 01-Jun-2010 15:11 3 KB ViggoHanst to previous | to last
2 01-Jun-2010 14:58 1 KB ViggoHanst to previous | to last
1 01-Jun-2010 14:42 646 bytes ViggoHanst to last

Page References

Incoming links Outgoing links

Version management

Difference between version and

At line 1 changed one line
The XDetector GUI is used for viewing EIS data as detector images. If the raster contains lines on both detectors, two xdetector windows, one for each CCD will pop up. The xdetector interface will look something like the image below, where two line windows each of 256 pixels width are displayed on CCD A. This raster contains is a test pattern from negineering tests at MSSL. The abscissa in the image is wavelength (here shown as pixel numbers) and the ordinate axis is position along the slit (again in pixels). Slit position could for real data translate to Solar-Y position.
[{ALLOW edit EISMainUsers}]
[{ALLOW view Anonymous}]
The XDetector GUI is used for viewing EIS data as detector images. If the raster contains lines on both detectors, two xdetector windows, one for each CCD will pop up. The xdetector interface will look something like the image below, where two line windows each of 256 pixels width are displayed on CCD A. This raster contains is a test pattern from engineering tests at MSSL. The abscissa in the image is wavelength (here shown as pixel numbers) and the ordinate axis is position along the slit (again in pixels). Slit position could for real data translate to Solar-Y position.
At line 21 changed one line
The other two buttons in the window action box also takes effect once a region of the CCD image is selected using the left mouse button. The __Average along wavelength__ has the effect that, instead of a magnified image of the slected region, a line plot, showing average count rates over the selected region in wavelength, is displayed for the range og slit postions selected.
The other two buttons in the window action box also takes effect once a region of the CCD image is selected using the left mouse button. The __Average along wavelength__ has the effect that, instead of a magnified image of the slected region, a line plot, showing average count rates over the selected region in wavelength, is displayed for the range of slit postions selected.
At line 25 changed one line
The slider labeled __exposure #__ is used to select exposure number when the raster contains more than one exposure. I.e. when the slider value is 1, the CCD image displays exposure nr 2 of the raster (slider counter starts at 0).
The slider labeled __exposure #__ is used to select exposure number when the raster contains more than one exposure. I.e. when the slider value is 1, the CCD image displays exposure number 2 of the raster (slider counter starts at 0).
At line 31 changed one line
The __Real size CCD display__ button is used to present the CCD image in real size, e.g. 2148 x 1024 pixels. This mainly for engineering purposes.
The __Real size CCD display__ button is used to present the CCD image in real size, e.g. 2148 x 1024 pixels. This is mainly for engineering purposes.